Startup and Connection
This page covers startup failures and server-connection problems.
Symptom: App starts but key modules fail to load
Checks:
- Verify Main Server process is running.
- Verify CoatFlex service is running when required.
- Confirm configured host and port values.
- Confirm local firewall allows service ports.
Symptom: Local help page cannot open
Checks:
- Verify Help directory exists under installed application path.
- Verify installer package includes latest build-local help files.
- Retry from menu after restart.
Symptom: Remote login verification fails
Checks:
- Verify network route to remote host.
- Verify credentials and access policy.
- Verify server-side authorization state.
Recovery Actions
- Restart related services.
- Re-load configuration and retry.
- If still failing, collect logs and escalate.
Collect Diagnostic Logs
- Open Main menu > Settings.
- In Export Diagnostic Logs, use Open to jump to the current runtime log directory.
- Use Export to generate a zip package before sending evidence to support.
- On installed Windows systems, the default runtime log directory is
%LOCALAPPDATA%\OSCLowE\log. - This directory contains the OSC client logs and the CoatFlex logs started by the client.