Sample Data
The Process Master module ships with a built-in sample dataset that demonstrates a complete Low-E double silver coating line scenario. This allows you to explore all features immediately after installation without manual data entry.
What's Included
The sample data creates a complete, ready-to-use environment with the following components:
| Component | Details |
|---|---|
| Coating Line | "Demo Line A" — a simulated Low-E double silver sputtering line |
| Film Design | 12-layer double silver stack (N/K/C/A/C/N/K/N/C/A/C/N) |
| Targets | 12 physical positions using 10 unique target configurations |
| Materials | Si, Zn:Al, NiCr, Ag targets with corresponding gas configurations |
| Gases | Ar (main gas), O₂ and N₂ (reactive gases) |
| Line Speed | 8 m/min |
| Measurement Positions | 33 positions across the glass width |
How to Load the Sample Data
The sample data is automatically injected during the database migration process:
- Go to Settings → Database Management
- Click the Update Database button
- The migration system will automatically create all sample data entries
- Navigate to the Process Master module
Layer-Target Mapping
The sample demonstrates how design layers map to physical target positions:
| Layer | Material | Position | Power |
|---|---|---|---|
| Protect | SiNx | T1 | 45 kW |
| L1 (Seed) | ZnAlO | T2 | 20 kW |
| L2 (Barrier) | NiCr | T3 | 12 kW |
| L3 (Silver 1) | Ag | T4 | 8 kW |
| L4 (Barrier) | NiCr | T5 | 12 kW |
| L5 (Middle) | SiNx | T6 | 50 kW |
| L6 (Middle) | ZnAlO | T7 | 25 kW |
| L7 (Isolation) | SiNx | T8 | 45 kW |
| L8 (Barrier) | NiCr | T9 | 14 kW |
| L9 (Silver 2) | Ag | T10 | 10 kW |
| L10 (Protect) | NiCr | T11 | 12 kW |
| L11 (Top) | SiNx | T12 | 45 kW |
ヒント
Positions T11 and T12 reuse the same target configurations as T3 (NiCr) and T1 (SiNx) respectively, demonstrating how a single target configuration can serve multiple physical positions.
Using the Sample Data
Once loaded, you can use the sample data to:
- Explore the Running Panel — View the coating line layout with all 12 target positions
- Load Running Configuration — Select "Demo Double Silver Running Config" to see the layer-target mapping
- Load Running Parameters — Select "Demo running at 8 m/min" to see the complete parameter snapshot
- Practice Reverse Engineering — Import test spectra and reverse-engineer layer thicknesses
- Practice Parameter Adjustment — Use the adjustment panel to simulate parameter optimization
Notes
- All sample data entries are prefixed with
DEMO_in their identifiers, making them easy to distinguish from your production data. - The sample data will not overwrite any existing entries. If you have already created data with the same identifiers, the sample entries will be skipped.
- The sample data references the built-in Double Silver Design template. Make sure this template exists in your material database (it is created during initial setup).